Discover Excellence

How To Calculate Cooling Capacity Of Cooling Tower In English Youtube

how To Calculate Cooling Capacity Of Cooling Tower In English Youtube
how To Calculate Cooling Capacity Of Cooling Tower In English Youtube

How To Calculate Cooling Capacity Of Cooling Tower In English Youtube In this video we will see "how to calculate cooling capacity of cooling tower in english" without any instrument with in short time.we have to just measure t. Cooling tower calculations: step by step guide!————————————————————— in order to lower the temperature of the water, air and.

Chiller cooling capacity how To Calculate The Engineering Mindset
Chiller cooling capacity how To Calculate The Engineering Mindset

Chiller Cooling Capacity How To Calculate The Engineering Mindset Helooo friends in this video we explain how to calculate heat load or cooling capacity of a cooling tower. we hope this video will help you.subscribe power. Understanding cooling tower capacity. the capacity of a cooling tower is a measure of how much heat it can remove from the cooling water, expressed in tons. a single ton of cooling is equivalent to the heat removal rate of 12,000 btus per hour. First, determine the water flow rate of the tower. for this example, the cooling tower has a water flow rate of 200 gallons per minute. next, determine the temperature differential of the cooling tower. for this cooling tower the difference is 50f. finally, calculate the cooling tower capacity using the formula above: ctc = 500 * q * t 12,000. Eff (%) = (ti to) (ti twb)*100. equation 1 : cooling tower efficiency. with : eff (%) = efficiency of the cooling tower. t i = water inlet temperature (°c or °f) t o = water outlet temperature (°c or °f) t wb = air web bulb temperature (°c or °f) some orders of magnitude : the difference of temperature in between the inlet and outlet.

english how To Calculate Efficiency of Cooling tower youtube
english how To Calculate Efficiency of Cooling tower youtube

English How To Calculate Efficiency Of Cooling Tower Youtube First, determine the water flow rate of the tower. for this example, the cooling tower has a water flow rate of 200 gallons per minute. next, determine the temperature differential of the cooling tower. for this cooling tower the difference is 50f. finally, calculate the cooling tower capacity using the formula above: ctc = 500 * q * t 12,000. Eff (%) = (ti to) (ti twb)*100. equation 1 : cooling tower efficiency. with : eff (%) = efficiency of the cooling tower. t i = water inlet temperature (°c or °f) t o = water outlet temperature (°c or °f) t wb = air web bulb temperature (°c or °f) some orders of magnitude : the difference of temperature in between the inlet and outlet. Capacity. the cooling tower's capacity is the product of the mass flow rate of water, specific heat, and temperature difference. this can also be expressed as heat rejected in kcal hr (btu h). evaporation loss. this is the amount of water that is evaporated during the cooling process. Cooling tower mass balance gives an indication about make up water requirement in system. cooling tower makeup is required due to water losses resulting from drift, evaporation & blowdown. water make up (m ) = total water losses = drift losses ( d) evaporation losses (e ) blow down losses (b) m = d e b.